● Auxiliary Heat Source Control Function
With its intelligent control system, the NEWNTIDE heat pump can maximize precise cooperation with the existing auxiliary heat sources, such as gas boilers, electric heaters, etc., to ensure efficient and stable operation of each other.
● Interlock with Solar Photovoltaic
The heat pump can receive signals about the power source and switch energy usage. When the electricity price is high, the heat pump runs as energy-saving as possible on the premise of ensuring the normal heating demand of the user. When electricity price is low, or even free (for example, from solar photovoltaic panels), the heat pump will use as much electric energy as possible. In this way, it will maximize energy efficiency and minimize running costs.
● Seven Modes
To better meet the different heating needs, the heat pump provides a variety of modes for users to select: a. Cooling, b. Heating, c. Auto, d. Hot water, e. Cooling + Hot water, f. Heating + Hot water, g. Auto+ Hot water. Seven modes can cover almost all heat pump usage scenarios of users. Once installed, the heat pump can automatically operate according to the user's needs, saving them the trouble of regularly adjusting the heat pump mode.
● Sterilization Function
By controlling the electric heater in the water tank, the temperature of the domestic hot water tank is heated to a higher temperature to kill the bacteria in it and protect the health of the user.
● User-friendly Operation Interface
The heat pump adopts an intelligent color screen wire controller, which allows users to operate all functions conveniently without the guidance of a professional installation and maintenance team. In addition, the wired controllers support interface customization to meet various needs.
● IoT Function
As modern heating equipment, IoT function is essential for operation management. With a built-in Wi-Fi module, the heat pump simplifies the installation process as users do not need to purchase and install the Wi-Fi module separately. Furthermore, it greatly meets the needs of users for remote control.
Model: NE-F | 60HCR4INEMIO | 90HCR4INEMIO | 130HCR4INEMIO | 160HCR4INEMIO |
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 30°C/35°C. | ||||
Heating Capacity (kW) | 1.68~5.88 | 2.25~8.39 | 3.42~12.38 | 4.67~15.57 |
Power Input (kW) | 0.27~1.27 | 0.37~1.82 | 0.56~2.75 | 0.79~3.56 |
COP | 6.22~4.63 | 6.08~4.61 | 6.11~4.50 | 5.91~4.37 |
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 50°C/55°C. | ||||
Heating Capacity (kW) | 1.09~5.13 | 1.76~7.60 | 2.31~10.53 | 2.74~13.70 |
Power Input (kW) | 0.25~1.97 | 0.42~2.96 | 0.56~4.18 | 0.62~5.18 |
COP | 4.36~2.60 | 4.19~2.57 | 4.13~2.52 | 4.42~2.64 |
[Space Cooling] Ambient Temp. (DB/WB): 35°C / -, Water Temp. (Inlet/Outlet): 12°C/7°C. | ||||
Cooling Capacity (kW) | 0.94~4.71 | 1.39~6.95 | 2.00~10.02 | 2.55~12.77 |
Power Input (kW) | 0.20~1.71 | 0.31~2.59 | 0.45~3.77 | 0.57~4.87 |
EER | 4.70~2.75 | 4.48~2.68 | 4.44~2.66 | 4.47~2.62 |
[Hot Water] Ambient Temp. (DB/WB): 20°C/15°C, Water Temp. from 15°C to 55°C | ||||
Heating Capacity (kW) | 7.1 | 10 | 12.47 | 17.12 |
Power Input (kW) | 1.68 | 2.35 | 2.98 | 3.38 |
COP | 4.23 | 4.26 | 4.27 | 4.47 |
Indoor Unit Info | ||||
Electric Heater (kW) | 3 | |||
Expansion Tank (L) | 8 | |||
Water Pipe Connection (inch) | G1'' | |||
Refrigerant outlet (mm) | Φ15.88 | |||
Refrigerant inlet (mm) | Φ6.35 | Φ9.52 | ||
Rated Water Flow (m³/h) | 1.03 | 1.55 | 2.24 | 2.75 |
Circulating Pump | Built-In | |||
Sound Pressure Level dB (A) at 1m | 28 | 32 | 32 | 34 |
Net Dimensions (mm) | 450×285×786 | |||
Water Proof Class | IPX1 | |||
Outdoor Unit Info | ||||
Compressor Brand | Panasonic | Panasonic | Panasonic | Mitsubishi |
Sound Pressure Level dB (A) at 1m | 43~53 | 43~54 | 43~55 | 44~55 |
Net Dimensions (L×W×H) (mm) | 960×425×710 | 1030×460×935 | 1030×460×935 | 1053×422×1360 |
Water Proof Class | IPX4 | |||
General Info | ||||
Power Supply | 220~240V~/50Hz | |||
ErP Level (35°C) | A+++ | |||
ErP Level (55°C) | A++ | |||
Max. Power Input (kW) | 5.1 (2.1+3) | 6.1 (3.1+3) | 7.5 (4.5+3) | 8.8 (5.8+3) |
Max. Running Current (A) | 23.2 (9.5+13.7) | 27.8 (14.1+13.7) | 34.1 (20.4+13.7) | 40 (26.4+13.7) |
Refrigerant | R32 | |||
Operation Range (°C) | -25~43 | |||
Max. Outlet Water Temp (°C) | 60 | |||
Electricity Shock Proof | Ⅰ |
Model: NE-F | 90HCR4TINEMIO | 130HCR4TINEMIO | 160HCR4TINEMIO | 185HCR4ITNEMIO | 200HCR4TINEMIO |
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 30°C/35°C. | |||||
Heating Capacity (kW) | 2.25~8.39 | 3.42~12.38 | 4.67~15.57 | 5.97~17.78 | 6.17~19.83 |
Power Input (kW) | 0.37~1.82 | 0.56~2.75 | 0.79~3.56 | 1.00~4.02 | 1.05~4.47 |
COP | 6.08~4.61 | 6.11~4.50 | 5.91~4.37 | 5.97~4.42 | 5.88~4.44 |
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 50°C/55°C. | |||||
Heating Capacity (kW) | 1.76~7.60 | 2.31~10.53 | 2.74~13.70 | 3.34~15.91 | 3.72~17.16 |
Power Input (kW) | 0.42~2.96 | 0.56~4.18 | 0.62~5.18 | 0.76~6.14 | 0.86~6.83 |
COP | 4.19~2.57 | 4.13~2.52 | 4.42~2.64 | 4.39~2.59 | 4.33~2.51 |
[Space Cooling] Ambient Temp. (DB/WB): 35°C / -, Water Temp. (Inlet/Outlet): 12°C/7°C. | |||||
Cooling Capacity (kW) | 1.27~6.66 | 1.78~9.71 | 2.26~12.45 | 3.03~14.68 | 3.28~16.80 |
Power Input (kW) | 0.31~2.64 | 0.42~3.81 | 0.56~4.95 | 0.69~5.56 | 0.76~6.44 |
EER | 4.10~2.52 | 4.24~2.55 | 4.04~2.52 | 4.39~2.64 | 4.32~2.61 |
[Hot Water] Ambient Temp. (DB/WB): 20°C/15°C, Water Temp. from 15°C to 55°C | |||||
Heating Capacity (kW) | 10 | 12.47 | 17.12 | 21.62 | 23.25 |
Power Input (kW) | 2.35 | 2.92 | 3.38 | 5 | 5.48 |
COP | 4.26 | 4.27 | 4.47 | 4.32 | 4.24 |
Indoor Unit Info | |||||
Electric Heater (kW) | 3/6/9 (optional) | ||||
Expansion Tank (L) | 8 | ||||
Water Pipe Connection (inch) | G1'' | ||||
Refrigerant outlet (mm) | Φ15.88 | ||||
Refrigerant inlet (mm) | Φ9.52 | ||||
Rated Water Flow (m³/h) | 1.55 | 2.24 | 2.75 | 3.18 | 3.44 |
Circulating Pump | Built-In | ||||
Sound Pressure Level dB (A) at 1m | 32 | 32 | 34 | 34 | 34 |
Net Dimensions (mm) | 450×285×786 | ||||
Water Proof Class | IPX1 | ||||
Outdoor Unit Info | |||||
Compressor Brand | Panasonic | Mitsubishi | |||
Sound Pressure Level dB (A) at 1m | 43~54 | 43~55 | 44~55 | 44~56 | 45~58 |
Net Dimensions (L×W×H) (mm) | 1030×460×935 | 1053×422×1360 | |||
Water Proof Class | IPX4 | ||||
General Info | |||||
Power Supply | 380~415V/3N~/ 50Hz | ||||
ErP Level (35°C) | A+++ | ||||
ErP Level (55°C) | A++ | ||||
Max. Power Input (kW) | 12.1 (3.1+9) | 13.5 (4.5+9) | 14.8 (5.8+9) | 15.6 (6.6+9) | 16.2 (7.2+9) |
Max. Running Current (A) | 19.2 (5.5+13.7) | 21.7 (8+13.7) | 23.8 (10.1+13.7) | 25.2 (11.5+13.7) | 26 (12.3+13.7) |
Refrigerant | R32 | ||||
Operation Range (°C) | -25~43 | ||||
Max. Outlet Water Temp (°C) | 60 | ||||
Electricity Shock Proof | Ⅰ |